ManageUPS Net Adapter +B

mun-p-b (18K)

The ManageUPS NET Adapter series provides an open approach to management of network power. ManageUPS +B simplifies integration of CHLORIDE UPS systems with Building Monitoring and Automation Systems via MODBUS RTU, MODBUS/TCP or JBUS protocols.

Ethernet services include DHCP client and WEB server for easy configuration and MODBUS/TCP server for easy migration from MODBUS RTU to MOBUS/TCP.

Selectable serial settings allow direct connection to RS232/422/485 networks without additional media converters.


Features

MODBUS/TCP
On-Board support for MODBUS/TCP over Ethernet -- future proof migration to BMS using industrial Ethernet.

Full Range Serial Network Support for MODBUS RTU and JBUS
Configurable Serial Communications configurable for various; RS232, RS422, RS485 full/half duplex -- eliminates expensive RS232 to RS485 media converters.

User-select termination -- connect ManageUPS to the middle or end of an existing MODBUS network.

Dual Network - Concurrent Services
Allows participation in MODBUS serial and MODBUS/TCP networks simultaneously. SNMP and full WEB services also operate concurrently in P Series models. View UPS system status in real time via WEB browser or BMS.

Easy MODBUS JBUS Configuration
WEB server interface for configuring serial port baud rate, device ID, offset, character timeout etc. or ethernet settings -- eliminates need for serial ports and terminal emulation software during on-site configuration.

ManageUPS accepts network parameters automatically via DHCP (RFC2131). In LANs without DHCP servers, ManageUPS negotiates a "link-local" address.

Use ManageUPS DCU (Discover and Configuration Utility for Windows) to automaticaly discover ManageUPS adapters on your LAN or ethernet crossover cable -- or, search for them on your WAN -- and quickly navigate to view status or change key settings.

Change network parameters to fixed IP settings if your network policy prefers manual IP administration.

On Board Help and Diagnostics
Help file "?" links on all WEB pages explain parameter definition and configuration settings -- including downloadable MODBUS Register map.

Diagnostics window allows view of serial communications traffic through the WEB Browser interface to simplify troubleshooting on new or complex serial networks.

Unified Register Map
All models of UPS in the Chloride portfolio are represented from a unified register map -- simplifies BMS software configuration in projects involving multiple UPS of different power ranges and model families.

Security
Web server can be disabled or secured with username and password access control. Web server uses basic HTTP authentication.

Serviceability
Allows firmware or configuration files to be updated over the network for simple maintenance. Using ManageUPS DCU for simplified updating and version management.


<< Top

New Features with P Series AMB

DHCP Network Configuration
Supports automatic configuration of IP settings using the DHCP protocol. DHCP server must be located on the same local network as the ManageUPS .

Multiple Networked Access Methods
Site power and UPS status information can be accessed securely from any computer on your network. View UPS system status in real time for situational decision support. Access via Telnet, SNMP, or Web Browser.

Network Shutdown
ManageUPS Network Shutdown Controller calls shutdown of computers running MopUPS NSA (Network Shutdown Agent) or RCCMD. Multiple schedules allow for graceful load shedding during extended outages to preserve battery autonomy for the most critical loads.

ManageUPS UPS Status Server allows computers running MopUPS Professional or MopUPS Special Edition for Parallel or Redundant Systems to share UPS status information. This allows server group administrators to tailor their own automated power-fail- response scenarios.

Both methods can be used simultaneously, and in various combinations to allow complete flexibility in tailoring sophisticated power-fail-response plans for a wide range of operating systems.

Event and Data Logging
On-board "flash drive" holds log files of UPS events, system events, & UPS data. WEB interface allows convenient log viewing utility and quick-link download button. Log files can also be retrieved via FTP.

Event Messaging
UPS events can trigger SNMP trap and/or e-mail event messages. E-mail message options include long, short and short-no-subject format options for easy forwarding via SMS or wireless handheld devices.

SNMP Agents
Embedded SNMP Agent conforms to SNMP RFC's -- RFC1213 (MIB II) and RFC1628 (Standard UPS MIB).

Simplified Network Configuration via DHCP and ManageUPS DCU.
Deploy-first, configure remotely -- or configure first, then deploy.
You choose what works best for your situation.

No need for cumbersome serial port setup and text menu configuration via terminal emulators in a staging area. Use ManageUPS DCU (Discover and Configuration Utility) to automatically discover ManageUPS adapters on your LAN -- or search for them on your WAN -- and quickly navigate to key settings WEB pages. Change network parameters to fixed IP settings if your network policy prefers manual IP administration.

ManageUPS accepts network parameters automatically via DHCP (RFC2131 & RFC2136 for DDNS).
In LANs without DHCP servers, ManageUPS negotiates a "link-local" address.

Environment Sensor - Optional*
Measures ambient temperature and relative humidity (RH), reads three (3) volt-free relay input contacts and controls one (1) output relay for event response. Add additional sensor modules to monitor multiple zones from one UPS network adapter. Flexible "Any or All" logic lets you pick multiple event triggers to drive the output relay control.

*Environment sensor measures and alarms are only available via WEB or SNMP -- not included in MODBUS map.


<< Top

Requirements
  • Network connection is 10/100 Base-T Ethernet - Ethernet Class 1 (DIX) packet format 802.3u Compliant - Compatible w/FastEthernet full/half duplex

  • Web interface requires a W3C standards compliant web browser

  • Automatic network configuration requires a DHCP Server

  • E-mail requires SMTP Server

  • SNMP trap requires SNMP trap receiver

  • Log functions work best with access to NTP (network time) server.


<< Top

UPS Support

Chloride Power Protection
Active, 70/80/90net, EDP 70 / 70L / 90 / 90 COC, Linear, Linear MKII, Synthesis, Synthesis Twin, Series E, CP3000 Series, PowerLAN, PowerLAN+

MasterGuard
Series A, E, Ei, C, D, S, Siii

ONEAC
ONEAC ON, Sinergy & Sinergy II


<< Top

Documentation

Quick Start Guides
For users who are somewhat familiar with networking and device management. The Quick Start Guide outlines ManageUPS automatic network configuration process and explains how to use ManageUPS Discovery and Configuration Utility (DCU) to simplify configuration and management of ManageUPS net Adapters. (PDF format)

ManageUPS P & VP

User Manuals
For users who are not familiar with networking and device management. The Users Guide reviews the information you need understand and use the product. (PDF format)

ManageUPS P & VP

Technical Files

RFC1628 UPS MIB
Chloride Environmental Sensor
MODBUS Register Map

Physical Installation Guides
You can select the Physical Installation Guide for your specific UPS by visiting the Download Section.


<< Top

Current Released Firmware

ManageUPS Net Adapter II should be kept up to date to ensure you have the latest drivers for your UPS type and current features. Installation instructions are included with the ZIP file you will download. Be sure to read the instructions prior to updating your adapter. If you have any problems be sure to use our Help Desk for support information.

Check if you have the latest firmware already installed on your card by going to the Administration > About ManageUPS page on your web interface. The currently installed firmware level and operating system level will be listed there.

Download the current ManageUPS Firmware


<< Top

How to Order

ManageUPS can be ordered from your local Chloride/MasterGuard/ONEAC vendor. The adapters are UPS specific, so be sure to specify your UPS type when ordering.


<< Top

Demonstration Information

To try a demo of the ManageUPS Adapter, please feel free to use any of out sample adapters that are currently online. We have an adapter for many different UPS systems, but not all are represented here. For a list of UPS compatibility please see above.

ManageUPS and MopUPS Demo - If you are demoing MopUPS at the same time you wish to demo ManageUPS you can use any of the listed adapters as MopNet hosts. Please keep in mind that these adapters are setup to send alarms out so to look like a real UPS. Be aware that your system may inadvertently shutdown if not configured properly.

Online Demo ManageUPS Adapters


<< Top


2009 Chloride Power Protection -- Privacy Policy